{"id":1237,"date":"2026-05-26T15:44:33","date_gmt":"2026-05-26T07:44:33","guid":{"rendered":"https:\/\/stalaser.com\/?post_type=product&#038;p=1237"},"modified":"2026-06-11T16:53:17","modified_gmt":"2026-06-11T08:53:17","slug":"4km-laser-rangefinder-module-2","status":"publish","type":"product","link":"https:\/\/stalaser.com\/zh\/product\/4km-laser-rangefinder-module-2\/","title":{"rendered":"4km Laser Rangefinder Module"},"content":{"rendered":"<p><strong><b>Product performance index:<\/b><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"194\">Item<\/td>\n<td colspan=\"2\" width=\"569\">Index<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Model<\/td>\n<td colspan=\"2\" width=\"569\">STA-H0407X<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Operating wavelength<\/td>\n<td colspan=\"2\" width=\"569\">1535nm \u00b110nm<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">\u00a0Eye-Safe<\/td>\n<td colspan=\"2\" width=\"569\">\u00a0Class\u00a01\u00a0(IEC 60825-1)<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Receiving Aperture<\/td>\n<td colspan=\"2\" width=\"569\">\u03a619mm<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Ranging range<\/td>\n<td colspan=\"2\" width=\"569\">20-7000m<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"194\">Range performance \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0observer visibility 12\u2009km<\/td>\n<td width=\"76\">7000m<\/td>\n<td width=\"492\">Typical large target,Maximum range<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">5500m<\/td>\n<td width=\"492\">\u00a0Big target,Reflectivity:0.6<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">4000m<\/td>\n<td width=\"492\">2.3\u2009\u00d7\u20092.3\u2009m target size,Reflectivity:0.3<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">1800m<\/td>\n<td width=\"492\">1\u2009\u00d7\u20091\u2009m target size,Reflectivity:0.1<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Communication Interface<\/td>\n<td colspan=\"2\" width=\"569\">RS422 \/ TTL<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Humidity<\/td>\n<td colspan=\"2\" width=\"569\">\u2264 60%<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Ranging accuracy<\/td>\n<td colspan=\"2\" width=\"569\">\u00b11m<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Accuracy rate<\/td>\n<td colspan=\"2\" width=\"569\">\u226598%<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Divergence angle<\/td>\n<td colspan=\"2\" width=\"569\">\u22640.5mrad<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Non-parallelism of the laser optical axis to the mounting reference<\/td>\n<td colspan=\"2\" width=\"569\">&lt;0.3mrad<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"194\">Ranging frequency<\/td>\n<td colspan=\"2\" width=\"569\">1~10hz\u00a0Conventional mode<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"569\">1~5Hz Low power mode\uff08Pre factory settings\uff09<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Size<\/td>\n<td colspan=\"2\" width=\"569\">\u226448.5mm\u00d736mm\u00d726mm<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Voltage<\/td>\n<td colspan=\"2\" width=\"569\">3.3-16V<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"194\">Electric current<\/td>\n<td width=\"76\">\u22641.35A<\/td>\n<td width=\"492\">Conventional mode\uff1aInstantaneous inrush current at power-on<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">\u22641A<\/td>\n<td width=\"492\">Low power mode\uff1aInstantaneous inrush current at power-on<\/td>\n<\/tr>\n<tr>\n<td width=\"76\">\u22640.01A<\/td>\n<td width=\"492\">Standby current. Note: The P-12 enable pin needs to be connected<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Power consumption<\/td>\n<td colspan=\"2\" width=\"569\">Standby power consumption \u22641W.<\/p>\n<p>Rated power consumption \u22641.6W.<\/p>\n<p>Peak power consumption \u22644W<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Working temperature<\/td>\n<td colspan=\"2\" width=\"569\">-40\u2103\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Storage temperature<\/td>\n<td colspan=\"2\" width=\"569\">-50\u2103\uff5e+75\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">Weight<\/td>\n<td colspan=\"2\" width=\"569\">\u226457g<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Notes:<\/b><\/strong><\/p>\n<p>1) NATO\u00a0target size 2.3 m \u00d7 2.3 m; Human target size 0.5 m \u00d7 1.7 m; Reflectivity 30%, observer visibility\u2265 25km.<\/p>\n<p><strong><b>Applications for the STA-H0407X Laser Rangefinder Module:<\/b><\/strong><\/p>\n<p>Thermal imaging, night vision and other handheld mobile devices<\/p>\n<p>Border observation and surveillance systems<\/p>\n<p>Sensor kits for UAV pods and UGVs<\/p>\n<p><strong><b>\u00a0<\/b><\/strong><strong><b>Ranging mode and ranging time:<\/b><\/strong><\/p>\n<p>a) Single maximum continuous ranging time: \u226535min;<\/p>\n<p>b) The maximum interval time for continuous distance measurement again: \u226415s.<\/p>\n<p>Laser optical axis stability \u2264 0.1mrad (full temperature range);<\/p>\n<p>Non-parallelism of the laser optical axis to the installation reference \u22640.25mrad;<\/p>\n<p><strong><b>Structure installation interface:<\/b><\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1240 size-full\" src=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe0.jpg\" alt=\"\" width=\"602\" height=\"268\" srcset=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe0.jpg 602w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe0-300x134.jpg 300w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe0-18x8.jpg 18w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe0-600x267.jpg 600w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p><strong><b>Electrical interface:<\/b><\/strong><\/p>\n<p>a) Communication interface RS422\/TTL communication;<\/p>\n<p>Baud rate: 115200;<\/p>\n<p>Data bit: 8;<\/p>\n<p>Starting position: 1;<\/p>\n<p>Stop position: 1;<\/p>\n<p>Checkpoint: None;<\/p>\n<p>&nbsp;<\/p>\n<p>b) External connectors;<\/p>\n<p>For each byte of information, the Least Significant Bit (LSB) is transmitted first. For multi-byte information, the lower-order byte is transmitted first. External interconnection testing is achieved using an NH1.0-12P terminal wire connector (with locking mechanism) to mate with the NH1.0-12AWB SMD (horizontal mount) connector on the ranging module side. The pin definitions for the power supply and communication interface on the ranging module side are shown in the table below.<\/p>\n<p>Table 1 Pin Definition<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"11.2400%\">Pin<\/td>\n<td width=\"14.0000%\">Grade<\/td>\n<td width=\"39.2400%\">Electrical Characteristics\u00a0Definition<\/td>\n<td width=\"35.4800%\">Remarks<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-\u00a01<\/td>\n<td width=\"14.0000%\">VIN+<\/td>\n<td rowspan=\"2\" width=\"39.2400%\">Input\u00a0Power\u00a0Positive<\/td>\n<td rowspan=\"4\" width=\"35.4800%\">Power supply<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-2<\/td>\n<td width=\"14.0000%\">VTN+<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-3<\/td>\n<td width=\"14.0000%\">COM<\/td>\n<td rowspan=\"2\" width=\"39.2400%\">Input\u00a0Power\u00a0Negative<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-4<\/td>\n<td width=\"14.0000%\">COM<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-5<\/td>\n<td width=\"14.0000%\">RS422_TXD+<\/td>\n<td rowspan=\"2\" width=\"39.2400%\">Signal output\u00a0port<\/td>\n<td rowspan=\"2\" width=\"35.4800%\">From\u00a0rangefinder to\u00a0host computer<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-6<\/td>\n<td width=\"14.0000%\">RS422_TXD-<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-7<\/td>\n<td width=\"14.0000%\">RS422_RXD-<\/td>\n<td rowspan=\"2\" width=\"39.2400%\">Signal\u00a0input\u00a0port<\/td>\n<td rowspan=\"2\" width=\"35.4800%\">From\u00a0host computer to\u00a0rangefinder<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-8<\/td>\n<td width=\"14.0000%\">RS422_RXD+<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-9<\/td>\n<td width=\"14.0000%\">TTL_TX<\/td>\n<td width=\"39.2400%\">Signal output port<\/td>\n<td width=\"35.4800%\">From rangefinder to host computer<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-10<\/td>\n<td width=\"14.0000%\">TTL_RX<\/td>\n<td width=\"39.2400%\">Signal input port<\/td>\n<td width=\"35.4800%\">From\u00a0host computer to\u00a0rangefinder<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-11<\/td>\n<td width=\"14.0000%\">TTL_GND<\/td>\n<td width=\"39.2400%\">Communication ground wire<\/td>\n<td width=\"35.4800%\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"11.2400%\">P-12<\/td>\n<td width=\"14.0000%\">WAKE_UP<\/td>\n<td width=\"39.2400%\">Wake\/Sleep<\/td>\n<td width=\"35.4800%\">High level wakes up, low level sleeps<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"100.0000%\"><strong><b>Interface connector<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"25.2600%\">NH1.0-12AWB SMD<\/td>\n<td width=\"39.2400%\">Horizontal mount<\/td>\n<td width=\"35.4800%\">&nbsp;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"25.2600%\">NH1.0-12P<\/td>\n<td width=\"39.2400%\">With locking mechanism<\/td>\n<td width=\"35.4800%\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The schematic diagram of pins 1-12\u00a0is as follows<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-1241 size-full\" src=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4.jpg\" alt=\"\" width=\"904\" height=\"493\" srcset=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4.jpg 904w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4-300x164.jpg 300w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4-768x419.jpg 768w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4-18x10.jpg 18w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72473-4-600x327.jpg 600w\" sizes=\"(max-width: 904px) 100vw, 904px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-1242 size-full\" src=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1.jpg\" alt=\"\" width=\"806\" height=\"320\" srcset=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1.jpg 806w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1-300x119.jpg 300w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1-768x305.jpg 768w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1-18x7.jpg 18w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/WPS\u62fc\u56fe1-600x238.jpg 600w\" sizes=\"(max-width: 806px) 100vw, 806px\" \/><\/p>\n<p>NH1.0-12AWB SMD\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0NH1.0-12P<\/p>\n<p>The installation center of gravity is shown in the following figure<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1243 size-full\" src=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1.jpg\" alt=\"\" width=\"1062\" height=\"510\" srcset=\"https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1.jpg 1062w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1-300x144.jpg 300w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1-1024x492.jpg 1024w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1-768x369.jpg 768w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1-18x9.jpg 18w, https:\/\/stalaser.com\/wp-content\/uploads\/2026\/05\/\u56fe\u72476-1-600x288.jpg 600w\" sizes=\"(max-width: 1062px) 100vw, 1062px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<div class=\"pro-canshu\">\n<div class=\"item\">\n<p class=\"canshu-name\">Range performance maximum<\/p>\n<p class=\"canshu-value\">7 km<\/p>\n<\/div>\n<div class=\"item\">\n<p class=\"canshu-name\">Range performance on 2.3 x 2.3 m<\/p>\n<p class=\"canshu-value\">4 km<\/p>\n<\/div>\n<div class=\"item\">\n<p class=\"canshu-name\">Typical accuracy<\/p>\n<p class=\"canshu-value\">\u00b11 m<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":1238,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-1237","product","type-product","status-publish","has-post-thumbnail","product_cat-1535nm-3-20km-lrf-module","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product\/1237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/comments?post=1237"}],"version-history":[{"count":2,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product\/1237\/revisions"}],"predecessor-version":[{"id":1495,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product\/1237\/revisions\/1495"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/media\/1238"}],"wp:attachment":[{"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/media?parent=1237"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product_brand?post=1237"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product_cat?post=1237"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/stalaser.com\/zh\/wp-json\/wp\/v2\/product_tag?post=1237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}